Medisca Logo
Login
0
Contact Us
LoginCreate an Account
0
US FlagEN
Medisca Logo
  • Who we serve
  • What's new
  • Products
  • Services
  • Formulas
  • Resources
  • Education
  • About us

Who we serve

  • 503A Pharmacies
  • 503B Outsourcing facilities
  • Cannabis industry
  • Contract manufacturing
  • Hospitals and clinics
  • Laboratory and research
  • Physicians and providers
  • Telehealth
  • Wholesalers

Products

  • Promotions
  • Our brands
  • Bases and vehicles
  • Capsules
  • Chemicals
  • Controlled substances
  • Devices
  • Equipment
  • Flavors, colors and oils
  • Lab supplies

Shop services

  • Formulation support
  • Standard operating procedures
  • Specialized consultations

Shop education

  • Education Catalog
  • Self-paced online learning
  • Seminars
  • Webinars
  • Hands-on lab training
  • Provider portals

Formulas & resources

  • Formula library
  • Sample formulas
  • BUDs library
  • Studies library
  • Medisca blog
  • Compounding 101

Customer service

  • Shipping policy
  • Return policy
  • CSOS registration

Company

  • About Medisca
  • Medisca quality
  • Careers
  • Press releases
  • Events

Account

  • Login
  • Create an account

Contact us

  • Customer service
  • 1-800-932-1039

Who we serve

  • 503A Pharmacies
  • 503B Outsourcing facilities
  • Cannabis industry
  • Contract manufacturing
  • Hospitals and clinics
  • Laboratory and research
  • Physicians and providers
  • Telehealth
  • Wholesalers

Products

  • Promotions
  • Our brands
  • Bases and vehicles
  • Capsules
  • Chemicals
  • Controlled substances
  • Devices
  • Equipment
  • Flavors, colors and oils
  • Lab supplies

Shop services

  • Formulation support
  • Standard operating procedures
  • Specialized consultations

Shop education

  • Education Catalog
  • Self-paced online learning
  • Seminars
  • Webinars
  • Hands-on lab training
  • Provider portals

Formulas & resources

  • Formula library
  • Sample formulas
  • BUDs library
  • Studies library
  • Medisca blog
  • Compounding 101

Customer service

  • Shipping policy
  • Return policy
  • CSOS registration

Company

  • About Medisca
  • Medisca quality
  • Careers
  • Press releases
  • Events

Account

  • Login
  • Create an account

Contact us

  • Customer service
  • 1-800-932-1039

Partners in Wellness

Change region

NABP

Copyright© 1989-

2026 Medisca Inc.
  • Privacy policy
  • Cookie policy
  • Terms & policies
  • Terms of Use
    1. Products
    2. Equipment
    3. Lyophilizers, Vacuum Pumps & Accessories
    4. Labconco FreeZone 6 Liter -50 C Console Freeze Dryer with Stoppering Tray Dryer, 230 V
    Labconco FreeZone 6 Liter -50 C Console Freeze Dryer with Stoppering Tray Dryer, 230 V

    Labconco FreeZone 6 Liter -50 C Console Freeze Dryer with Stoppering Tray Dryer, 230 V

    This Freeze Dryer is designed for lyophilizing moderate to large sample loads and stoppering vials or serum bottles under vacuum. The newly integrated Lyo-Works OS provides a real-time display of information such as the collector temperature, the vacuum level, and the end-point detection system (optional), shown on a 5" full-color, capacitive touch screen.

     

    Product Dimensions: W 32" × D 30" × H 64"

    • Console:
    • 3/4 hp HCFC / CFC-free refrigeration system to cool collector to -58 °F / -50 °C
    • Brushed stainless steel and glacier white, epoxy-coated steel exterior with blue accents
    • Upright stainless steel collector coil and chamber
    • LCD that displays system operating parameters, set-up parameters and alarm messages
    • Red alarm light that flashes and beeper that sounds to indicate that an abnormal system event has occurred, including: power failure, improper line voltage supply, collector temperature rise above -40 °C, service vacuum pump (after 1000 hours of vacuum use), and moisture in collector
    • Moisture sensor that prevents refrigeration or vacuum start-up when moisture is detected in the collector chamber area
    • Vacuum break valve that bleeds air into the system when power to the freeze dryer or vacuum pump is shut off
    • LED vacuum and temperature "waves" for at-a-glance display of relative system vacuum and collector temperature
    • Vacuum control valve that maintains setpoint vacuum level
    • Rear-mounted RS-232 port to transmit data to a user-supplied computer. Transmission intervals may be user-configured for 10, 30, 60, 300, or 600 seconds
    • Automatic start-up switch for collector cool-down and vacuum pull-down with manual override switches
    • Retractable, 9" collector drain hose
    • Power switch and rear-mounted electrical receptacle (for vacuum pump connection)
    • 3/4" OD vacuum connection, three feet of 3/4" ID vacuum hose and two clamps Stoppering Tray Dryer:
    • Brushed stainless steel and epoxy-coated steel exterior
    • 1" thick acrylic door
    • 3 temperature probes for monitoring sample or shelf temperature
    • 3" diameter outlet for connection to FreeZone System
    • 3 processing shelves, each W 16.5" × D 12" (41.9 cm × 30.5 cm) with 196 square inches of area
    • 1 hp HCFC / CFC-free refrigeration system and 1000-watt electric heater for cooling and heating fluid medium circulating through channels in the shelves from -40 °C to 40 °C
    • LCD for display of system and probe temperatures in °C or °F, vacuum in mBar, Pa or Torr, and the segment of the program in progress
    • Microprocessor-controlled temperature ramp and hold programming from -40 °C to 40 °C and memory to store five programs and repetition of identical protocols
    • Control panel with operating switches, stoppering control know, vacuum release valve control knob and 1/8" OD backfill port
    • Red LED alarm indicator
    • Rear-mounted RS232 port, interconnect cable and power switch
    • Console:
    • 3/4 hp HCFC / CFC-free refrigeration system to cool collector to -58 °F / -50 °C
    • Brushed stainless steel and glacier white, epoxy-coated steel exterior with blue accents
    • Upright stainless steel collector coil and chamber
    • LCD that displays system operating parameters, set-up parameters and alarm messages
    • Red alarm light that flashes and beeper that sounds to indicate that an abnormal system event has occurred, including: power failure, improper line voltage supply, collector temperature rise above -40 °C, service vacuum pump (after 1000 hours of vacuum use), and moisture in collector
    • Moisture sensor that prevents refrigeration or vacuum start-up when moisture is detected in the collector chamber area
    • Vacuum break valve that bleeds air into the system when power to the freeze dryer or vacuum pump is shut off
    • LED vacuum and temperature "waves" for at-a-glance display of relative system vacuum and collector temperature
    • Vacuum control valve that maintains setpoint vacuum level
    • Rear-mounted RS-232 port to transmit data to a user-supplied computer. Transmission intervals may be user-configured for 10, 30, 60, 300, or 600 seconds
    • Automatic start-up switch for collector cool-down and vacuum pull-down with manual override switches
    • Retractable, 9" collector drain hose
    • Power switch and rear-mounted electrical receptacle (for vacuum pump connection)
    • 3/4" OD vacuum connection, three feet of 3/4" ID vacuum hose and two clamps Stoppering Tray Dryer:
    • Brushed stainless steel and epoxy-coated steel exterior
    • 1" thick acrylic door
    • 3 temperature probes for monitoring sample or shelf temperature
    • 3" diameter outlet for connection to FreeZone System
    • 3 processing shelves, each W 16.5" × D 12" (41.9 cm × 30.5 cm) with 196 square inches of area
    • 1 hp HCFC / CFC-free refrigeration system and 1000-watt electric heater for cooling and heating fluid medium circulating through channels in the shelves from -40 °C to 40 °C
    • LCD for display of system and probe temperatures in °C or °F, vacuum in mBar, Pa or Torr, and the segment of the program in progress
    • Microprocessor-controlled temperature ramp and hold programming from -40 °C to 40 °C and memory to store five programs and repetition of identical protocols
    • Control panel with operating switches, stoppering control know, vacuum release valve control knob and 1/8" OD backfill port
    • Red LED alarm indicator
    • Rear-mounted RS232 port, interconnect cable and power switch